Allied Air Enterprises WARM AIR GAS FURNACE 92G1UH User Manual

Page 24

Advertising
background image

506724-01

Page 24 of 57

Issue 1108

FIGURE 28

VENT TERMINATION CLEARANCES

FOR NON−DIRECT VENT INSTALLATIONS IN THE USA AND CANADA

K

D

E

L

B

C

F

G

A

B

J

A

M

I

H

INSIDE CORNER

DETAIL

VENT TERMINAL

AIR SUPPLY INLET

AREA WHERE TERMINAL
IS NOT PERMITTED

Fixed

Closed

Operable

B

Fixed

Closed

Operable

B

B

A =

B =

C =

D =

E =

F =

G =

H =

I =

J =

K =

L =

M =

US Installations

1

Canadian Installations

2

12 inches (305mm) or 12 in. 305mm)

above average snow accumulation.

12 inches (305mm) or 12 in. 305mm)

above average snow accumulation.

Clearance above grade, veranda,

porch, deck or balcony

Clearance to window or

door that may be opened

4 feet (1.2 m) below or to side of opening;

1 foot (30 cm) above opening

6 inches (152mm) for appliances <10,000

Btuh (3kw), 12 inches (305mm) for

appliances > 10,000 Btuh (3kw) and

<100,000 Btuh (30kw), 36 inches (.9m)

for appliances > 100,000 Btuh (30kw)

Clearance to permanently

closed window

Vertical clearance to ventilated soffit

located above the terminal within a

horizontal distance of 2 feet (mm)

from the center line of the terminal

Clearance to unventilated soffit

Clearance to outside corner

Clearance to inside corner

Clearance to each side of center line ex-

tended above meter / regulator assembly

Clearance to service regulator

vent outlet

Clearance to non−mechanical air

supply inlet to building or the com-

bustion air inlet to any other ap-

pliance

Clearance to mechanical air sup-

ply inlet

Clearance above paved sidewalk or

paved driveway located on public property

Clearance under veranda, porch,

deck or balcony

* 12"

* Equal to or greater than soffit depth.

*

* 3 feet (.9m)

* 12"

3 feet (.9m) within a height 15 feet (4.5m)

above the meter / regulator assembly

3 feet (.9m)

6 inches (152mm) for appliances <10,000

Btuh (3kw), 12 inches (305mm) for

appliances > 10,000 Btuh (3kw) and

<100,000 Btuh (30kw), 36 inches (.9m)

for appliances > 100,000 Btuh (30kw)

3 feet (.9m) above if within 10 feet

(3m) horizontally

6 feet (1.8m)

1

In accordance with the current ANSI Z223.1/NFPA 54 Natural Fuel Gas Code

2

In accordance with the current CSA B149.1, N

atural Gas and Pr opane Inst allation Code

between two single family dwellings and serves both dwellings.

sides beneath the floor. Lennox recommends avoiding this location if possible.

4 feet (1.2 m) below or to side of opening;

1 foot (30 cm) above opening

* Equal to or greater than soffit depth.

* Equal to or greater than soffit depth.

* Equal to or greater than soffit depth.

* No minimum to outside corner

* No minimum to outside corner

3 feet (.9m) within a height 15 feet (4.5m)

above the meter / regulator assembly

*For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1,
clearance will be in accordance with local installation codes and the re-
quirements of the gas supplier and these installation instructions."

*

*