INSTALLATION

Setting Equipment

Upflow Applications

The gas furnaces can be installed as shipped in the upflow

position. Refer to Figure 10 for clearances. Select a location

that allows for the required clearances that are listed on the

unit nameplate. Also consider gas supply connections,

electrical supply, vent connection, condensate trap and drain

connections, and installation and service clearances [24

inches (610 mm) at unit front]. The unit must be level from

side to side. Tilt the unit slightly (maximum 1/2 in. from

level) from back to front to aid in the draining of the heat

exchanger. See Figure 9.

Allow for clearances to combustible materials as indicated

on the unit nameplate.

Shipping Bolt Removal

Units with 1/2 hp blower motor are equipped with three

flexible legs and one rigid leg. The rigid leg is equipped with

a shipping bolt and a flat white plastic washer (rather than

the rubber mounting grommet used with a flexible mounting

leg). See Figure 8. The bolt and washer must be removed

before the furnace is placed into operation. After the

bolt and washer have been removed, the rigid leg will not

touch the blower housing.

WARNING

Blower access panel must be securely in place when

blower and burners are operating. Gas fumes, which

could contain carbon monoxide, can be drawn into living

space resulting in personal injury or death.

WARNING

Do not connect the return air ducts to the back of the

furnace. Doing so will adversely affect the operation of

the safety control devices, which could result in personal

injury or death.

Figure 8

Units with 1/2 HP

Blower Motor

Figure 9

SETTING EQUIPMENT

Tilt the unit slightly (Max. 1/2”) from back to front to aid in the draining of

the heat exchanger.

Unit must be level side-to-side in all applications.