A95UH, A93UH, 95G1UH &92G1UH Gas Furnace

The A95UH/A93UH/95G1UH & 92G1UH Category IV gas

furnace is shipped ready for installation in the upflow or

horizontal position. The furnace is shipped with the bottom

panel in place. The bottom panel must be removed if the

unit is to be installed in horizontal or upflow applications with

bottom return air.

The A95UH/A93UH/95G1UH & 92G1UH can be installed

as either a Direct Vent or a Non-Direct Vent gas central

furnace

The furnace is equipped for installation in natural gas

applications. A conversion kit (ordered separately) is required

for use in propane/LP gas applications.

NOTE: In Direct Vent installations, combustion air is taken

from outdoors and flue gases are discharged outdoors. In

Non-Direct Vent installations, combustion air is taken from

indoors and flue gases are discharged outdoors. See Figure

2 for applications involving roof termination.

Shipping and Packing List

1 - Assembled Gas Furnace

1 - Bag assembly containing the following:

3 - Wire nuts

1 - Snap bushing

1 - Snap Plug

1 - Wire tie

1 - Condensate trap

1 - Condensate trap cap

1 - Condensate trap clamp

1 - 2” diameter debris screen

Check equipment for shipping damage. If you find any

damage, immediately contact the last carrier.

Please refer to specification sheets for available accessories.

Safety Information

As with any mechanical equipment, personal injury can

result from contact with sharp sheet metal edges. Be

careful when you handle this equipment.

CAUTION

DANGER OF EXPLOSION!

DANGER

There are circumstances in which odorant used with LP/

Propane gas can lose its scent. In case of a leak, LP/

Propane gas will settle close to the floor and may be difficult

to smell. An LP/Propane leak detector should be installed

in all LP applications.

Use only the type of gas approved for use with this furnace.

Refer to unit nameplate.

A95UH/A93UH/95G1UH & 92G1UH units are CSA

International certified to ANSI Z21.47 and CSA 2.3 standards.

Building Codes

In the USA, installation of gas furnaces must conform with

local building codes. In the absence of local codes, units

must be installed according to the current National Fuel Gas

Code (ANSI Z223.1/NFPA 54). The National Fuel Gas Code

is available from the American National Standards

Institute, Inc., 11 West 42nd Street, New Your, NY 10036.

In Canada, installation must conform with current National

Standard of Canada CSA-B149 Natural Gas and Propane

Installation Codes, local plumbing or waste water codes and

other applicable local codes.

In order to ensure proper unit operation in non-direct vent

applications, combustion and ventilation air supply must be

provided according to the current National Fuel Gas Code

or CSA-B149 standard.

Improper installation, adjustment, alteration, service or

maintenance can cause property damage, personal injury

or loss of life. Installation and service must be performed

by a licensed professional installer (or equivalent), service

agency or the gas supplier.