FIGURE 22

TYPICAL

EXHAUST PIPE CONNECTIONS IN UPFLOW DIRECT OR

NON−DIRECT VENT APPLICATIONS

TRANSITION

2”

2”

2”

3”

2”

2”

or

Pipe size determined in table 5

DO NOT transition

from smaller to larger

pipe in horizontal runs

of exhaust pipe.

EXHAUST

*2”

* When transitioning up in pipe size, use the shortest length of 2” PVC pipe possible.

NOTE − Exhaust pipe and intake pipe must be the same diameter.

or

FIGURE 23

TRANSITION

SIDE VIEW

2”

2”

2”

2”

or

TYPICAL EXHAUST PIPE CONNECTIONS IN HORIZONTAL DIRECT OR

NON−DIRECT VENT APPLICATIONS

(RIGHT HAND DISCHARGE SHOWN)

3”

2”

45°

MAX

45°

MAX

DO NOT transition

from smaller to larger

pipe in horizontal runs

of exhaust pipe.

EXHAUST

12" max.

*2”

*2”

* When transitioning up in pipe size, use the shortest length of 2” PVC pipe possible.

NOTE − Exhaust pipe and intake pipe must be the same diameter.