6 mounting a new lamp unit, Mounting a new lamp unit, Image 16-9) – Barco CLM R10+ User Manual

Page 179

Advertising
background image

16. Servicing

Image 16-9
Take out the lamp

For recycling guidelines of the lamp, see "Recycling guidelines", page 8.

16.6 Mounting a new lamp unit

About the lamp units

All four lamp units are equal. A spare lamp can be inserted in any position without problems. See spare part list for the order
numbers.

W

ARNING

:

This procedure may only be performed by qualified technical service personnel.

C

AUTION

:

Never attempt to disassemble the lamp from its housing or to dispose of it. Due to its high internal

pressure, the lamp may explode in either hot or cold states if improperly handled. For recycling guidelines,
see "Recycling guidelines", page 8
.

C

AUTION

:

Never touch the reflector or the lamp bulb with your fingers. That will reduce the lifetime of the

lamp.

Never touch the UV filter when a lamp is removed.

Necessary tools

No tools.

How to insert a lamp unit

1. Insert the lamp vertically into the housing, with the front of the lamp facing the middle of the projector. (image 16-10)

2. Rotate the fixation handle and close it. Push till it clicks.

3. Insert the cable connector into lamp unit socket.

R59770021 CLM R10+ 11/10/2010

175