9 over temperature dmd safety, Over temperature dmd safety, Service menu – Barco CLM R10+ User Manual

Page 168

Advertising
background image

14. Service menu

Load custom settings

1. Connect a FAT 16 formatted USB device to the USB port.

2. Press MENU to activate the menus.

3. Use the ▲ or ▼ key to select Service and press ENTER.

The service window opens.

4. Use the ▲ or ▼ key to select USB memory and press ENTER.

5. Use the ▲ or ▼ key to select Load custom settings and press ENTER.

An list of serial numbers is given.

6. Use the ▲ or ▼ key to select the serial number to start from to load the settings.

The settings from the selected projector on the USB device are loaded into the current attached projector. The current projector
settings are overwritten with these settings. (image 14-52, image 14-53, image 14-54)

Image 14-52

Image 14-53

Image 14-54

14.9 Over temperature DMD safety

What can be done

When the temperature of the DMD becomes higher than the normal operation temperature (between 60 and 64 °C) it is possible to
switch the lamp mode of the projector automatically from 4 lamps to 2 lamps so that the DMD temperature can cool down. A warning
remains on the local LCD panel and the warning LED is on as long as the temperature is too high. When the temperature exceeds
64°C then the projector is switched to standby and an error is displayed on the LCD panel.

How to configure the over temperature safety

1. Press MENU to activate the menus.

2. Use the ▲ or ▼ key to select Service and press ENTER.

3. Use the ▲ or ▼ key to select Safety and press ENTER.

4. Use the ▲ or ▼ key to select Overtemp DMD and press ENTER to toggle between [On] and [Off].

On

When temperature is too high, lamp mode is switched from 4 to 2 lamps. The 4 lamps mode can only be restored
after switching first to standby and restarting the projector.

If the temperature exceeds 64 °C, the projector is switched to standby.

Off

for a temperature between 60 and 64 °C the projector continues in normal operation but the warning is set on the
LCD display. Once the temperature is higher then 64 °C, then the projector is switched to standby.

The following text is displayed on the LCD: “DMD temperature to high. Please, check cooling liquid level ! Check
dust filters ! Press any key to confirm.”

See image 14-55, image 14-56, image 14-57.

164

R59770021 CLM R10+ 11/10/2010

Advertising