C. DMX Chart

C. DMX CHART

Overview

CLM control channel mapping (Full mode)

CLM control channel mapping (Basic mode)

C.1 CLM control channel mapping (Full mode)

Overview

Chan-
nel

Function

Type Range Default Action

Comments

1

Intensity

Xfade0 - 255

0 - 100%

2

Brightness

Xfade0 - 255 128

0 - 100%

The value is + / - so the value needs to be 128
to be “Normal”

3

Contrast

Xfade0 - 255 128

0 - 100%

The value is + / - so the value needs to be 128
to be “Normal”

0 - 7

0

No function

8 - 15

Layout Main Full Screen

16 - 23

Layout PiP top right

24 - 31

Layout Split left - right

32 - 39

Layout Split top - bottom

40 - 47

Layout 5

48 - 55

Layout 6

56 - 63

Layout 7

64 - 71

Layout 8

72 - 79

Layout 9

80 - 87

Layout 10

88 - 95

Input 1

96 -
103

Input 2

104 -
111

Input 3

Not for CLM

112 -
119

Input 4

Not for CLM

4

Input Select

120 -
255

Future assignment

0 - 31

No function

31 - 63

Focus motor

64 - 95

Zoom motor

96 -
127

Lens R - L

128 -
159

Lens Up - Down

160 -
191

Power On / Lamp On

Together with both Motor Go channels (channel
6 & 7) held in 255 for 5 seconds.

192 -
223

Stand By / Lamp off

Together with both Motor Go channels (channel
6 & 7) held in 255 for 5 seconds.

5

Function Select

224 -
255

Future assignment