E. troubleshooting, E.1 error codes, Error codes – Barco CLM R10+ User Manual

Page 207

Advertising
background image

E. Troubleshooting

E. TROUBLESHOOTING

E.1 Error codes

Overview

When the error code is preceded by a ’-’ sign, then the error means a real error for the projector.

When the error code is preceded by a ’+’ sign, then the error code means a warning. The projector does not fail yet, but take care
for the warning and try to resolve the problem. A warning state can turn into an error state.

Not all error codes can have two states. When the state is available, it is indicated by a Yes in the overview table. When the state
is not available, it is indicated by a No.

Error
code

Description

Error

Warning

Caused by

Action

1001

Wrong lamp 1
parameters

Yes

-

Wrong lamp/ no communication
with lamp

Check lamp type

Call a qualified service engineer

1002

Wrong lamp 2
parameters

Yes

-

Wrong lamp/ no communication
with lamp

Check lamp type

Call a qualified service engineer

1003

Wrong lamp 3
parameters

Yes

-

Wrong lamp/ no communication
with lamp

Check lamp type

Call a qualified service engineer

1004

Wrong lamp 4
parameters

Yes

-

Wrong lamp/ no communication
with lamp

Check lamp type

Call a qualified service engineer

1011

Lamp 1 missing

Yes

Yes

No lamp inserted in position 1

Insert a lamp in position 1

1012

Lamp 2 missing

Yes

Yes

No lamp inserted in position 2

Insert a lamp in position 2

1013

Lamp 3 missing

Yes

Yes

No lamp inserted in position 3

Insert a lamp in position 3

1014

Lamp 4 missing

Yes

Yes

No lamp inserted in position 4

Insert a lamp in position 4

1021

Lamp 1 broken

Yes

-

Lamp 1 is not ON

Check installation of lamp 1
(connection, cable, etc.)

1022

Lamp 2 broken

Yes

-

Lamp 2 is not ON

Check installation of lamp 2
(connection, cable, etc.)

1023

Lamp 3 broken

Yes

-

Lamp 3 is not ON

Check installation of lamp 3
(connection, cable, etc.)

1024

Lamp 4 broken

Yes

-

Lamp 4 is not ON

Check installation of lamp 4
(connection, cable, etc.)

1399

I²C open error

Yes

1398

I²C read error

Yes

1397

I²C write error

Yes

1699

Formatter busy

1697

Formatter init
failed

Yes

-

no communication with formatter
ctrl

Call a qualified service engineer

1696

Formatter ctrl
init failed

Yes

-

no communication with formatter
ctrl

Call a qualified service engineer

1695

Formatter start
failed

Yes

-

no communication with formatter

Call a qualified service engineer

1693

1692

1691

2100

LPS 1 error

Yes

-

Replace LPS

2400

LPS 2 error

Yes

-

Replace LPS

2700

LPS 3 error

Yes

-

Replace LPS

3000

LPS 4 error

Yes

-

Replace LPS

R59770021 CLM R10+ 11/10/2010