9. Image menu

Image 9-62

Image 9-63

Image 9-64

Image 9-65

9.5.2

Advanced settings

About the advanced settings

Clamp delay

The time between the leading edge of the clamp pulse and the locked edge of the sync pulse. Can be
any value between 0 and 255.

Clamp width

The width of the clamp pulse can be any value between 0 and 255.

Sync
pulse

Clamp
pulse

Clamp
delay

Clamp
width

L

ead

in

g

ed

g

e

Tr

ai

lin

g

ing e

d

ge

Image 9-66

Field polarity

The field polarity function is used for interlaced images. Both rasters of the image could be shifted in a
wrong way (double lines are visible in the image). This can be corrected by forcing the field polarity
to [neg] or [pos].

How to change the clamp delay - clamp width?

1. Press MENU to activate the menus.

2. Use the ▲ or ▼ key to select Image and press ENTER.

3. Use the ▲ or ▼ key to select Timings and press ENTER.

4. Use the ▲ or ▼ key to select Advanced settings and press ENTER.

The Advanced settings menu is displayed.

88