Error
code

Description

Error

Warning

Caused by

Action

7908

Fan inlet A low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7906

Fan inlet B low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7904

Fan lamp 1
back low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7902

Fan lamp 2
back low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7900

Fan lamp 3
back low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7899

Fan lamp 3
back high

-

Yes

7898

Fan lamp 4
back low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7896

Fan prism low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7894

Fan color
wheel low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7892

Fan lamp 1
front low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7890

Fan lamp 2
front low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7888

Fan lamp 3
front low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7886

Fan lamp 4
front low

Yes

Yes

Fan is running too slow or not at all

If problem persists, call a qualified
service engineer

7884

Pump speed
low

Yes

Yes

Bad or no water flow in the cooling
circuit

If problem persists, call a qualified
service engineer

7883

Pump speed
high

-

Yes

Ignore this message

7878

Over temp

Yes

Yes

extreme overheading of DMD or
lamps

If problem persists, call a qualified
service engineer

7877

Under temp

DMD too cold

Warm up the projector

7876

SMPS input
range

Supplied voltage is out of range

Check supplied voltage range

7875

DMD temp
open

Yes

Yes

Sensor not connected

If problem persists, call a qualified
service engineer

7874

DMD temp
short

Yes

Yes

short circuit in sensor circuit

If problem persists, call a qualified
service engineer

7873

Ambient temp
open

Yes

Yes

Sensor not connected

If problem persists, call a qualified
service engineer

7872

Ambient temp
short

Yes

Yes

short circuit in sensor circuit

If problem persists, call a qualified
service engineer

7871

TEC temp open

Yes

Yes

Sensor not connected

If problem persists, call a qualified
service engineer

7870

TEC temp short

Yes

Yes

short circuit in sensor circuit

If problem persists, call a qualified
service engineer

7865

Lamp 1 run
time msg
exceeded

-

Yes

Run time of lamp 1 will be exceeded

Replace the lamp with a new one.
Call a qualified service engineer

7864

Lamp 1 run
time warning
exceeded

-

Yes

Run time of lamp 1 is exceeded

Replace the lamp with a new one.
Call a qualified service engineer

7863

Lamp 1 run
time max
exceeded

-

Yes

The maximum run time for the lamp
is exceeded

Replace the lamp with a new one.
Call a qualified service engineer

R59770021 CLM R10+ 11/10/2010