Introduction

Transmission of the master angle

3.3

Transmission of the master angle

The master value/angle can be transmitted via the following transmission media:

r

Digital frequency (simulation of an incremental encoder)

r

System bus (CAN)

r

ETHERNET Powerlink

The transmission medium is selected according to the criteria listed in the below table:

3.4

Speed or angular synchronism?

The decision whether to use a speed or angular synchronism mainly refers to the TA

"Electronic gearbox".

Angular synchronism
Use the angular synchronism if the material is not able to absorb any force and no

remaining positional variation must be available. Please note that a position controller

always causes additional trouble in a track since disturbances and reference value

variations must be compensated exactly.

Speed synchronism
Use the speed synchronism if the material is able to absorb force which ensures a better

concentricity.

3.5

Rail or cascade structure?

Rail structure
All drives obtain the same master value/master angle.

Transmission medium

Criterion

Digital frequency

System bus (CAN)

ETHERNET Powerlink

Network structure

Rail or cascade

Rail

Rail or cascade

Master value/master angle

transmission

Only relative

Absolute or relative

Absolute or relative

Max. resolution

16 bits/revolution

24 bits/revolution

24 bits/revolution

Cable length

Virtually unlimited, but

max. 50 m from drive to

drive.

Depends on baud rate,

number of nodes and

cable cross-section.

With a baud rate of

500 kbits/s the total

cable length is limited to

e.g. 117 metres.

Virtually unlimited, but

max. 100 m from drive to

drive.

Additional hardware required

Digital frequency

extension module

(E94AYFLF)

No, interface is already

integrated in

9400 HighLine (CAN on

board).

ETHERNET Powerlink

communication module

(E94AYCEP)

* In preparation; at present 16 bits/revolution