9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Selection of master value source and output

4.4.2

Master value source: Digital frequency input

To use the digital frequency input as master value source, the controller must be provided

with digital frequency extension module (E94AYFLF).
To ensure the integration of the extension module in the application, the TA "Synchronism

with mark synchronisation" must be used as technology application.

4.4.3

Master value source: Bus system

When the master value is selected via a bus system as e.g. system bus (CAN) it is possible

to first extrapolate the received position information to compensate higher bus

transmission cycles.

r

Parameter setting: Tab Application parameters  dialog level Overview  Synchronism


Master value extrapolation

r

Configuration: Tab FB editor  FB

MotionBusIn

Note!

The technology application "Synchronism with mark synchronisation"

MotionBus" which can also be selected in the application catalog does not

contain any interfaces to the digital frequency extension module.

Parameter

Lenze setting

Value Unit

C03550

Number of extrapolation cycles

1

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

FALSE  Activate extrapolation

C03058/9