13 hysttpdiffshaft, 14 hysttpdifftool – Lenze E94AxHE Technology Application Synchronism User Manual

Page 62

Advertising
background image

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Parameterisable function blocks

62

L

EDS94TA10040xxxx EN 1.1 - 10/2008

4.14.13

HystTPDiffShaft

4.14.14

HystTPDiffTool

Is an instance of

Function

L_SdSetPosition

Mark synchronisation (master value):

Conversion of the TP hysteresis selected in the real units of the machine via C03656

into a position in [increments].



Mark synchronisation (master value) (C 34)

Parameter

Possible settings

Information

C03656

-214000.0000

unit

214000.0000 Position value

• Initialisation: 0.0000 unit

C03657

String of digits

Position unit

• Read only

C03658

-2147483647

2147483647 Status

• Read only

Is an instance of

Function

L_SdSetPosition

Mark synchronisation (setpoint):

Conversion of the TP hysteresis selected in the real units of the machine via C03876

into a position in [increments].



Mark synchronisation (setpoint) (C 39)

Parameter

Possible settings

Information

C03876

-214000.0000

unit

214000.0000 Position value

• Initialisation: 0.0000 unit

C03877

String of digits

Position unit

• Read only

C03879

-2147483647

2147483647 Status

• Read only

Advertising