Signal configuration

4.12.1

Drive and motor interface

If required, the preset signal configuration of the control and setpoint inputs of the drive

and motor interface can be easily reconfigured per parameter setting of the assigned

multiplexer parameters.

Drive interface

Motor interface

Signal (Lenze setting)

Control input

Signal configuration

FALSE  Set controller inhibit

C03130/1

DIGIN 5  Reset error 1

C03130/2

Control word 1 bit 07  Reset error 2

C03130/3

FALSE  Reset error 3

C03130/4

FALSE  Set error

C03130/5

Control word 1 bit 00  Switch on drive

C03130/6

Signal (Lenze setting)

Setpoint input

Signal configuration

100 %  Position controller adaptation

C03141/1

100 %  Phase controller adaptation

C03141/2

100 %  Speed controller adaptation

C03141/3

100 %  Upper torque limit value

C03141/4

-100 %  Lower torque limit value

C03141/5

100 %  Flux setpoint

C03141/6

100 %  Adaptation of mass inertia

C03141/7