19 monitfollowerror, 20 motionbusin – Lenze E94AxHE Technology Application Synchronism User Manual

Page 69

Advertising
background image

EDS94TA10040xxxx EN 1.1 - 10/2008

L

69

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Parameterisable function blocks

4.14.19

MonitFollowError

4.14.20

MotionBusIn

C03874

Set position reached

• Display of output signal

bInTarget.

0 Set position not yet reached.
1 Set position reached.

Parameter

Possible settings

Information

Is an instance of

Function

L_LdMonitFollowError

Following error monitoring

Parameter

Possible settings

Information

C03960

-214748.3647

unit

214748.3647 Following error at the input

• Display of input signal

dnFollowErrorIn_p in real unit of

the machine.

C03961

String of digits

Position unit

• Read only

C03963

Following error out of tolerance

• Read only

FALSE Following error smaller than set

switching threshold

TRUE Following error larger than set

switching threshold

C03964

Following error monitoring activated

• Read only

FALSE Deactivated

TRUE Activated

Is an instance of

Function

L_LdExtrapolate

Optional extrapolation of the position information received via a bus system in

order to compensate for larger bus transmission cycles.



Master value source: Bus system (C 31)

Parameter

Possible settings

Information

C03550

1

127 Number of extrapolation cycles

• Initialisation: 1

C03551/1

String of digits

Position unit

• Read only

C03551/2

String of digits

Speed unit

• Read only

C03557

-214748.3647

unit/t

214748.3647 Speed at the output

• Read only

• Is generated from the speed

signal dnSpeedOut_s.

C03558

-214748.3647

unit

214748.3647 Position at the output

• Display of the dnPosOut_p output

signal in the real unit of the

machine.

Advertising