Lenze E94AxHE Technology Application Synchronism User Manual

Page 73

Advertising
background image

EDS94TA10040xxxx EN 1.1 - 10/2008

L

73

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Parameterisable function blocks

C03831

-2147483647

unit/t

2147483647 Speed at the input

• Read only

• Is generated from the speed

signal dnSetSpeedIn_s.

C03832

-2147483647

unit/t

2147483647 Speed at the output

• Read only

• Is generated from the speed

signal dnSpeedOut_s.

C03833

-214748.3647

unit

214748.3647 Set position at the output

• Display of output signal

dnSetPosCycle_p in real unit of the

machine.

C03834

-214748.3647

unit

214748.3647 Actual position at the output

• Display of output signal

dnActPosCycle_p in real unit of the

machine.

C03835

-214748.3647

unit

214748.3647 Following error

• Display of output signal

dnFollowErrore_p in real unit of

the machine.

C03836

-214748.3647

unit

214748.3647 Measured TP deviation

• Display of output signal

dnDifference_p in real unit of the

machine.

C03837

-214748.3647

unit

214748.3647 Measured cycle

• Display of output signal

dnTpTpDistance_p in real unit of

the machine.

C03838

-214748.3647

unit

214748.3647 TP set position at the input

• Display of the dnTpPos_p input

signal in the real unit of the

machine.

Parameter

Possible settings

Information

Advertising