Lenze E94AxHE Technology Application Synchronism User Manual

Page 78

Advertising
background image

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Parameterisable function blocks

78

L

EDS94TA10040xxxx EN 1.1 - 10/2008

C03570/1

0.010

s

130.000 Ramp for manual jog

• Initialisation: 1.000 s

C03570/2

0.010

s

130.000 Ramp for continuous operation/

single cycle

• Initialisation: 1.000 s

C03570/3

0.010

s

130.000 Stop ramp

• Initialisation: 1.000 s

C03571/1

String of digits

Position unit

• Read only

C03571/2

String of digits

Speed unit

• Read only

C03572

-214748.3647

unit/t

214748.3647 Reference speed

• Read only

• Reference value for selecting

speeds.

C03579

-2147483647

2147483647 Status

• Display of the bit-coded output

signal dnState.

C03580

Master position in the target

• Same as output bInTarget

• Read only

0 No
1 Yes

C03581

-214748.3647

unit

214748.3647 Cycle

• Read only

C03582

-214748.3647

unit

214748.3647 Master position at the output

• Display of the dnPosOut_p output

signal in the real unit of the

machine.

C03583

-214748.3647

unit

214748.3647 External master position at the input

• Display of input signal

dnExtMaster_p in real unit of the

machine.

Parameter

Possible settings

Information