2 mark synchronisation (master value) – Lenze E94AxHE Technology Application Synchronism User Manual

Page 34

Advertising
background image

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

"Synchronism" mode"

34

L

EDS94TA10040xxxx EN 1.1 - 10/2008

4.5.2

Mark synchronisation (master value)

[4-6]

"Mark synchronisation" function in signal flow (schematic diagram)

This function serves to carry out a mark synchronisation of the master value via touch

probe sensor.

r

Parameter setting: Tab Application parameters  dialog level Overview  Synchronism


Master value processing

r

Configuration: Tab FB editor  FB

ElectricalShaftVal

n

Master value

o

Master value with stretch factor

Œ



M

v

Slave

Real master/

Virtual master

C03006 = 0

v

t

Dj

Dj

Dj

TP

TP

Note!

For this purpose, the touch probe sensor must be connected to the digital input

DI3!

Parameter

Lenze setting

Value Unit

C03023

Master value synchronisation (TP)

Deactivated

C03612

TP position (register)

0.0000 unit

C03651

TP limit

1.0000 unit

C03656

Hysteresis

0.0000 unit/t

2