4.14.27
TrimmingOffsetAdjustment
4.14.28
Virtual_Master
C03704
Set position reached
• Display of output signal
bInTarget.
0 Set position not yet reached.
1 Set position reached.
Parameter
Possible settings
Information
Is an instance of
Function
L_SdSetPosition
Conversion of the offset position selected in the real units of the machine via
C03676 into a position in [increments].
Parameter
Possible settings
Information
C03676
-214000.0000
unit
214000.0000 Position value
• Initialisation: 0.5000 unit
C03677
String of digits
Position unit
• Read only
C03678
-2147483647
2147483647 Status
• Read only
Is an instance of
Function
L_LdVirtualMasterP
"Virtual master"
Master value source: Virtual master (C 30)
Parameter
Possible settings
Information
C03565
Virtual master operating mode
0 Continuous operation
Lenze setting
1 Inching
2 Handwheel function
C03566
0.0000
unit
214000.0000 Target position
• The target position must be
within the cycle.
• Initialisation: 0.0000 unit
C03567
0.0000
unit
214000.0000 Starting position
• The starting position must be
within the cycle.
• Initialisation: 0.0000 unit
C03568/1
-214000.0000
unit/t
214000.0000 Master speed 1
• Initialisation: 1.0000 unit/t
C03568/2
-214000.0000
unit/t
214000.0000 Master speed 2
• Initialisation: 1.0000 unit/t
C03569/1
0.0000
unit/t
214000.0000 Manual speed CW rotation
• Initialisation: 1.0000 unit/t
C03569/2
0.0000
unit/t
214000.0000 Manual speed CCW rotation