L

39

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

"Synchronism" mode"

4.5.6

Mark synchronisation (setpoint)

[4-10] "Mark synchronisation" function in signal flow (schematic diagram)

This function serves to carry out a mark synchronisation of the setpoint via touch probe

sensor.

r

Parameter setting: Tab Application parameters  dialog level Synchronism  Overview


Setpoint processing

r

Configuration: Tab FB editor  FB

ToolControl

n

Master value with trimming

o

Actual value

Œ



M

v

Slave

Real master/

Virtual master

C03006 = 0

v

t

Dj

Dj

Dj

TP

TP

Note!

For this purpose, the touch probe sensor must be connected to the digital input

DI2!

Parameter

Lenze setting

Value Unit

C03033

Tool synchronisation (TP)

Deactivated

C03851

Positive TP limit

1.0000 unit

C03876

TP limit - hysteresis

0.0000 unit

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

FALSE  Set TP position

C03058/24