22 shaftstartposition, 23 toolcontrol – Lenze E94AxHE Technology Application Synchronism User Manual

Page 72

Advertising
background image

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Parameterisable function blocks

72

L

EDS94TA10040xxxx EN 1.1 - 10/2008

4.14.22

ShaftStartPosition

4.14.23

ToolControl

C03983

DIS:bPosTeach

• Display of input signal bPosTeach.

0 FALSE
1 TRUE

C03984

DIS:bBusy

• Display of output signal bBusy.

0 Profile parameters are available.
1 Conversion active, no access to

profile parameters at the moment.

C03985

-2147483647

2147483647 Status

• Display of the bit-coded output

signal dnState.

Parameter

Possible settings

Information

Is an instance of

Function

L_SdSetPosition

Conversion of the master shaft starting position selected in the real units of the

machine via C03034 into a position in [increments].

Parameter

Possible settings

Information

C03034

-214000.0000

unit

214000.0000 Position value

• Initialisation: 0.0000 unit

C03035

String of digits

Position unit

• Read only

C03036

-2147483647

2147483647 Status

• Read only

Is an instance of

Function

L_LdToolControl



Setpoint processing (C 38)

Parameter

Possible settings

Information

C03825

-2147483647

2147483647 Status

• Display of the bit-coded output

signal dnState.

C03826/1

String of digits

Position unit

• Read only

C03826/2

String of digits

Speed unit

• Read only

C03827

-214748.3647

unit/t

214748.3647 Reference speed

• Read only

• Reference value for selecting

speeds.

C03830

-2147483647

unit/t

2147483647 Correction speed at the input

• Read only

• Is generated from the speed

signal dnTpMakeUpLeeway_s.

Advertising