EDS94TA10040xxxx EN 1.1 - 10/2008

L

35

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

"Synchronism" mode"

TP profile parameters

r

Parameter setting: Tab Application parameters  dialog level Overview  TP profile

parameters

r

Configuration: Tab FB editor  FB

MarkSynchronizationShaft

TP interface

r

Parameter setting: Tab Application parameters  dialog level Overview  TP interface

Parameter

Lenze setting

Value Unit

C03620

Positioning mode

0

C03621

Deactivation mode

0

C03623/1

Positive speed

3600.0000 unit/t

C03623/2

Negative speed

3600.0000 unit/t

C03626/1

Acceleration ramp

1.000 s

C03626/2

Deceleration ramp

1.000 s

C03626/3

Stop ramp

1.000 s

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

FALSE  Activate master value TP correction

C03058/12

Parameter

Lenze setting

Value Unit

C02810/3

Signal delay TP3

0 μs

C03022

Edge evaluation of positive edge

TRUE

C03024

Edge evaluation of negative edge

FALSE