background image

EDS94TA10040xxxx EN 1.1 - 10/2008

L

59

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Parameterisable function blocks

4.14.8

ElectricalShaftData

Is an instance of

Function

L_SdSetAxisData

Mapping of the machine parameters of the higher-level drive (master shaft).



Master axis (master shaft) (C 26)

Parameter

Possible settings

Information

C03930

1

2147483647 Gearbox ratio - numerator

• Initialisation: 1

C03931

1

2147483647 Gearbox ratio - denominator

• Initialisation: 1

C03932

0.0001

Unit/incr.

214748.3647 Feed constant

• Initialisation: 360 units/incr.

C03933

Path unit

0 User-defined

Selection in C03934

1 Inc
2 μm
3 mm
4 m
5 inch
6 yard
7 °

Lenze setting

C03934

Character string, max. 8 characters

User-defined path unit

C03935

At present, the unit of the time base is

permanently set to "s" and cannot be

changed!

Time unit

C03938

0.0000

unit

214748.3647 Cycle

• Initialisation: 360 unit

C03939

10

Bit

24 Resolution of encoder revolution

• Initialisation: 16 bits

C03941

-214748.3647

unit/t

214748.3647 Reference speed

• Initialisation:

36000.0000 units/t

C03942

Traversing range

0 Unlimited
1 Limited
2 Modulo

Lenze setting

C03948

-2147483.647

2147483.647 Resulting gearbox factor

• Read only

C03949

-214748.3647

Incr.

214748.3647 Resolution - application unit

• Read only

Advertising