9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Machine parameters

28

L

EDS94TA10040xxxx EN 1.1 - 10/2008

Example of determining the machine parameters for the slave axis

O

Tip!
The feed constant corresponds to the movement on the machine side when the

gearbox output shaft carries out one revolution (for selection as angle = 360°).
When the unit is set, the real unit of the machine for the selection of physical

values (e. g. speeds, accelerations and decelerations) is defined.

1. Set gearbox ratio for the motor in the form of a quotient

(numerator and denominator): i

2

= 12.612 = 12612/

1000
– Numerator (C02520) = 12612
– Denominator (C02521) = 1000

2. Set the same gearbox ratio for the position encoder:

– Numerator (C02522) = 12612
– Denominator (C02523) = 1000

3. Set feed constant (C02524).

– For the conveyor drive: Vk = d

2

* π = 628,3185 mm

4. Set the selection "mm" as unit (C02525).

d

2

i

2

= 200 mm

= 12.612