10 limiter, Parameter setting & configuration limiter – Lenze E94AxHE Technology Application Synchronism User Manual

Page 46

Advertising
background image

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Limiter

46

L

EDS94TA10040xxxx EN 1.1 - 10/2008

4.10

Limiter

[4-15] Basic function "Limiter" (schematic diagram)

r

Parameter setting: Tab Application parameters  dialog level Overview  Limiter

The basic function "Limiter" monitors the

travel range limits via limit switches and

parameterised software limit positions

and can lead the drive to defined limit

ranges when being asked accordingly by

the safety module.

v

t

t

M

Slave

n

t

LS_Limiter

n

t

LS_Quickstop

STOP

Parameter

Lenze setting

Value Unit

Limit values
C02707

Permissible direction of rot.

Positive and negative

C02700

Software limit positions are active

Deactivated

C02701/1

Positive software limit position

0.0000 unit

C02701/2

Negative software limit position

0.0000 unit

Only for homing, positioning and manual jog
C02702

Limitations are active

Deactivated

C02703

Max. speed

3600.0000 unit/s

C02705

Max. acceleration

3600.0000 unit/s

2

C02706

Min. S-ramp time

100 ms

Limited speed 1 ... 4 (only for homing, positioning, and manual jog)
C02708/1

Limited speed 1

3600.0000 unit/s

C02710/1

Delay lim. speed 1

0.0100 unit/s

2

C02711/1

S-ramp time lim. speed 1

100 ms

C02708/2

Limited speed 2

7200.0000 unit/s

C02710/2

Delay lim. speed 2

0.0100 unit/s

2

C02711/2

S-ramp time lim. speed 2

100 ms

C02708/3

Limited speed 3

14400.0000 unit/s

C02710/3

Delay lim. speed 3

0.0100 unit/s

2

C02711/3

S-ramp time lim. speed 3

100 ms

C02708/4

Limited speed 4

28800.0000 unit/s

C02710/4

Delay lim. speed 4

0.0100 unit/s

2

C02711/4

S-ramp time lim. speed 4

100 ms

For manual jog only
C02713

Max. dist. manual jog

360.0000 unit

Advertising