L

EDS94TA10040xxxx EN 1.1 - 10/2008

4.11

Brake control

[4-16] Basic function "Brake control" (schematic diagram)

r

Parameter setting: Tab Application parameters  dialog level Overview  Brake control

The basic function "Brake control" serves to the wear free

control and monitoring of a holding brake.
In the simplest case, an optionally available brake module

is used.
Alternatively the holding brake can also be controlled and

monitored via the digital inputs/outputs.

M

LS_Brake

Note!

In the Lenze setting the brake control is switched off to reach a safe status after

mains connection.

Parameter

Lenze setting

Value Unit

C02580

Operating mode of brake

Brake control off

C02581

Brake activation threshold

50 rpm

C02582

Brake resp. to pulse inhibit

Activate the brake immediately

C02583

Status input monitoring

Not active

C02585

Brake control polarity

Not inverted

C02586

Starting torque 1

0.00 Nm

C02587

Starting torque 2

0.00 Nm

C02588

Starting torque source

Starting torque 1/2

C02589

Brake closing time

100 ms

C02590

Brake opening time

100 ms

C02591

Waiting time - status monitoring

100 ms

C02593

Waiting time - brake activation

0.000 s

C02594

Test torque

0.00 Nm

C02595

Permissible angle of rotation

5 °

C02596

Grinding speed

100 rpm

C02597

Accel./decel. time - grinding

1.000 s

C02598

Grinding ON time

0.5 s

C02599

Grinding OFF time

0.5 s