Master value processing

[4-5]

"Master value processing" function in the signal flow (schematic diagram)

r

Parameter setting: Tab Application parameters  dialog level Overview  Synchronism


Master value processing

r

Configuration: Tab FB editor  FB

ElectricalShaftVal

n

Master value

o

Master value with stretch factor

M

v

Slave

Real master/

Virtual master

v

t

Dv

C03006 = 0

Œ



Parameter

Lenze setting

Value Unit

C03587

Master value

- unit

C03000

Stretch factor - numerator

1000000000

C03001

Stretch factor - denominator

1000000000

C03025

Master value - direction of rotation

Not inverted

C03034

Starting position

0.0000 unit

C03938

Cycle (register)

360.0000 unit

C03672

Master value with stretch factor

- unit

Setpoint inputs of the function

Signal configuration

Lenze setting

Setpoint input

(Multiplexer parameters)

DIGIN CINH  Set starting position of master shaft

C03058/11

C03034  Master shaft starting position

C03053/1

C03000  Stretch factor - numerator

C03050/1

C03001  Stretch factor - denominator

C03050/2