15 limittpdiffshaft, 16 limittpdifftool – Lenze E94AxHE Technology Application Synchronism User Manual

Page 63

Advertising
background image

EDS94TA10040xxxx EN 1.1 - 10/2008

L

63

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Parameterisable function blocks

4.14.15

LimitTPDiffShaft

4.14.16

LimitTPDiffTool

Is an instance of

Function

L_SdSetPosition

Mark synchronisation (master value):

Conversion of the TP limit selected in the real units of the machine via C03651 into

a position in [increments].



Mark synchronisation (master value) (C 34)

Parameter

Possible settings

Information

C03651

-214000.0000

unit

214000.0000 Position value

• Initialisation: 0.0000 unit

C03652

String of digits

Position unit

• Read only

C03653

-2147483647

2147483647 Status

• Read only

Is an instance of

Function

L_SdSetPosition

Mark synchronisation (setpoint):

Conversion of the TP limit selected in the real units of the machine via C03851 into

a position in [increments].



Mark synchronisation (setpoint) (C 39)

Parameter

Possible settings

Information

C03851

-214000.0000

unit

214000.0000 Position value

• Initialisation: 0.0000 unit

C03852

String of digits

Position unit

• Read only

C03853

-2147483647

2147483647 Status

• Read only