2 actual value and status signals – Lenze E94AxHE Technology Application Synchronism User Manual

Page 24

Advertising
background image

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Assignment of the I/O terminals

24

L

EDS94TA10040xxxx EN 1.1 - 10/2008

4.2.2

Actual value and status signals

The following tables contain the Lenze assignment of the analog and digital outputs for

the "Synchronism" technology application.

r

The default signal configuration if required can be easily changed by parameterising

the multiplexer parameters assigned.

Analog outputs

Digital outputs

State bus

Display elements

Terminal X3

Signal (Lenze setting)

Signal configuration

AO1

Motor speed

• Scaling: ±10 V ≡ motor reference speed (C00011)

C03110/1

AO2

Motor torque (setpoint)

• Scaling: ±10 V ≡ Motor reference torque (C00057/2)

C03110/2

Terminal X4

Signal (Lenze setting)

Signal configuration

DO1

Status "Drive ready"

• DC-bus voltage is available and no error has occurred.

C03100/1

DO2

Status "Electrical shaft enabled"

C03100/2

DO3

Status "Limitation active"

• A setpoint is limited at the moment.

C03100/3

DO4

"Error" status

• If the controller is in the error state, the digital output DO4 is set

to HIGH level.

C03100/4

Terminal X2

Signal (Lenze setting)

Signal configuration

SB

"Application error" status

• The state bus is put in the "error" status.

C03100/5

User LED

Signal (Lenze setting)

Signal configuration

Status "Electrical shaft enabled"

C03100/6

GA

AO1

AO2

GO

24O

DO1

DO2

DO3

DO4

GE

24E

SB