EDS94TA10040xxxx EN 1.1 - 10/2008

L

55

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Parameterisable function blocks

4.14.2

ClutchElectricalShaft

Is an instance of

Function

L_LdClutchAxisP

Time-controlled virtual clutch with position reference



Virtual clutch (C 36)

Parameter

Possible settings

Information

C03665/1

0.010

s

130.000 Clutch in ramp

• Acceleration ramp for

synchronising to the master shaft.

• Initialisation: 1.000 s

C03665/2

0.010

s

130.000 Decoupling ramp

• Deceleration ramp for stop of

master position.

• Initialisation: 2.000 s

C03665/3

0.010

s

130.000 Ramp for positive opening operation

• Deceleration ramp for positive

opening operation.

• Initialisation: 1.000 s

C03666/1

String of digits

Position unit

• Read only

C03666/2

String of digits

Speed unit

• Read only

C03667

-214748.3647

unit/t

214748.3647 Reference speed

• Read only

• Reference value for selecting

speeds.

C03669

-2147483647

2147483647 Status

• Display of the bit-coded output

signal dnState.

C03671

-214748.3647

unit

214748.3647 Set position after decoupling

• Display of the dnOpenPosition_p

input signal in the real unit of the

machine.

C03672

-214748.3647

unit

214748.3647 Actual position of the master angle

• Display of input signal

dnActPostion_p in real unit of the

machine.

C03673

-214748.3647

unit

214748.3647 Master position at the input

• Display of input signal

dnSetPostion_p in real unit of the

machine.

C03674

-214748.3647

unit

214748.3647 Master position at the output

• Display of the dnPosOut_p output

signal in the real unit of the

machine.