Rockwell Automation 1403-NDNET DeviceNet Communications Card Installation Instructions User Manual

Page 114

Advertising
background image

Publication 1403-IN054B-EN-P - August 2001

B-84 DeviceNet Data Tables

877

16

th

harmonic

Float

4

See Instance 41, parameter 9 (harmonic magnitude for I3)

878

17

th

harmonic

Float

4

See Instance 43, parameter 9 (harmonic magnitude for I3)

879

18

th

harmonic

Float

4

See Instance 41, parameter 10 (harmonic magnitude for I3)

880

19

th

harmonic

Float

4

See Instance 43, parameter 10 (harmonic magnitude for I3)

881

20

th

harmonic

Float

4

See Instance 41, parameter 11 (harmonic magnitude for I3)

882

21

st

harmonic

Float

4

See Instance 43, parameter 11 (harmonic magnitude for I3)

883

22

nd

harmonic

Float

4

See Instance 42, parameter 1 (harmonic magnitude for I3)

884

23

rd

harmonic

Float

4

See Instance 44, parameter 1 (harmonic magnitude for I3)

885

24

th

harmonic

Float

4

See Instance 42, parameter 2 (harmonic magnitude for I3)

886

25

th

harmonic

Float

4

See Instance 44, parameter 2 (harmonic magnitude for I3)

887

26

th

harmonic

Float

4

See Instance 42, parameter 3 (harmonic magnitude for I3)

888

27

th

harmonic

Float

4

See Instance 44, parameter 3 (harmonic magnitude for I3)

889

28

th

harmonic

Float

4

See Instance 42, parameter 4 (harmonic magnitude for I3)

890

29

th

harmonic

Float

4

See Instance 44, parameter 4 (harmonic magnitude for I3)

891

30

th

harmonic

Float

4

See Instance 42, parameter 5 (harmonic magnitude for I3)

892

31

st

harmonic

Float

4

See Instance 44, parameter 5 (harmonic magnitude for I3)

893

32

nd

harmonic

Float

4

See Instance 42, parameter 6 (harmonic magnitude for I3)

894

33

rd

harmonic

Float

4

See Instance 44, parameter 6 (harmonic magnitude for I3)

895

34

th

harmonic

Float

4

See Instance 42, parameter 7 (harmonic magnitude for I3)

896

35

th

harmonic

Float

4

See Instance 44, parameter 7 (harmonic magnitude for I3)

897

36

th

harmonic

Float

4

See Instance 42, parameter 8 (harmonic magnitude for I3)

898

37

th

harmonic

Float

4

See Instance 44, parameter 8 (harmonic magnitude for I3)

899

38

th

harmonic

Float

4

See Instance 42, parameter 9 (harmonic magnitude for I3)

900

39

th

harmonic

Float

4

See Instance 44, parameter 9 (harmonic magnitude for I3)

901

40

th

harmonic

Float

4

See Instance 42, parameter 10 (harmonic magnitude for I3)

902

41

st

harmonic

Float

4

See Instance 44, parameter 10 (harmonic magnitude for I3)

903

Fundamental

Float

4

See Instance 43, parameter 1 (phase angle for I3)

904

2

nd

harmonic

Float

4

See Instance 41, parameter 2 (phase angle for I3)

905

3

rd

harmonic

Float

4

See Instance 43, parameter 2 (phase angle for I3)

906

4

th

harmonic

Float

4

See Instance 41, parameter 3 (phase angle for I3)

907

5

th

harmonic

Float

4

See Instance 43, parameter 3 (phase angle for I3)

908

6

th

harmonic

Float

4

See Instance 41, parameter 4 (phase angle for I3)

909

7

th

harmonic

Float

4

See Instance 43, parameter 4 (phase angle for I3)

910

8

th

harmonic

Float

4

See Instance 41, parameter 5 (phase angle for I3)

911

9

th

harmonic

Float

4

See Instance 43, parameter 5 (phase angle for I3)

912

10

th

harmonic

Float

4

See Instance 41, parameter 6 (phase angle for I3)

913

11

th

harmonic

Float

4

See Instance 43, parameter 6 (phase angle for I3)

914

12

th

harmonic

Float

4

See Instance 41, parameter 7 (phase angle for I3)

Param # Parameter name

Data type #bytes

Comment

Advertising