Assembly structure common services – Rockwell Automation 1403-NDNET DeviceNet Communications Card Installation Instructions User Manual

Page 65

Advertising
background image

Publication 1403-IN054B-EN-P - August 2001

DeviceNet Data Tables B-35

Instance 29 Attributes (Min/max configuration/readback
parameter select)

Assembly Structure

Common Services

Attribute
ID

Access
Rule

Name

DeviceNet
Data Type

3

Set

Data

Structure of
8 bytes (4 Words)

Param #

Parameter name

Data type

#bytes

Master Module Range

Default
Setting

Word
No.

1

Password

Int

2

-1, 0-9999
Correct password is required to
configure/reconfigure min/max functionality,
but not required to select a min/max record
to be read back in the min/max read
assembly. If the user is only selecting a
min/max record to be read, set password to –
1.

0

1

2

Min/max parameter
record to be read

Int

2

1 to 84
Specifies a specific min/max record to be
read.

2

3

Enable/disable
min/max log

Int

2

0 = Disable
1 = Enable

1

3

4

Clear min/max log

Int

2

Write a 1 here to clear the min/max log;
otherwise write a 0.

4

Service
Code

Service Name

10

hex

Set_Attributes_Single

Advertising