Rockwell Automation 8520 9/Series Hardware TAB 5 User Manual

Page 21

Advertising
background image

Section 5A
9/440 Resolver–based CNC/Drive System

5A-19

Figure 5A.11
Series C Axis Module Cable Clamp

2.

Prepare one end of the motor cable for attachment to the cable shield
clamp by removing the outer installation and braided shield from the
motor cable. Ensure approximately 51 mm (2.0 in.) of the insulated
cable wires are exposed (see Figure 5A.11).

3.

Remove another 22 mm (0.875 in.) of insulation to expose the
braided shield underneath for clamp attachment.

Important: When cutting into the insulation, use care not to cut into the
braided shield underneath.

4.

Position the cable shield clamp over the exposed braided shield
(ensure clamp screw is behind clamp and not braided shield).

5.

Tighten the clamp screw.

Important: Do not overtighten the clamp screw or damage to the braided
shield may result.

6.

Thread the bracket screw into the bottom of the axis module and
tighten.

7.

Connect an axis module connector kit (catalog number 1394–199) to
each motor cable that you will use. Refer to the instructions included
with the kit for the specific connections.

Advertising