5a.8, 5a.8 general wiring overview – Rockwell Automation 8520 9/Series Hardware TAB 5 User Manual

Page 68

Advertising
background image

Section 5A
9/440 Resolver–based CNC/Drive System

5A-66

Check your 9/Series CRT for any drive faults that may have occurred and
are displayed as an error.

Axis Module LEDs
The Axis module has a Status LED visible thru the front cover. It is:

LED

Indicates

STATUS

Steady Green

bus up, axis enabled

Flashing Green

bus up, axis not enabled

Flashing Red/Green ready, bus not up
Flashing Red

fault present

Steady Red

hardware malfunction

For more details on how to diagnose and troubleshoot your axis module refer to the 1394 Digital AC
Multi-Axis Motion Control System Users Manual
(publication 1394-5.0).

The following figure shows a typical interconnect diagram for a 9/440
Resolver–based CNC to 1326 motors. Note this figure illustrates only one
servo motor with optional feedback encoder. The 9/440 Resolver–based
CNC can support up to four servo’s and two spindle drives.

5A.8
General Wiring Overview

Advertising