background image

Location of TB5

on Wiring Board

P1
+

WATCHDOG

XILINX

TB4

J5

TB2 TB3

TB5

SHLD

GND

TPIN

+5V

Section 5A
9/440 Resolver–based CNC/Drive System

5A-30

Figure 5A.18
Wiring Board Detail

Series A/B Wiring Board

Drive Interface

P1
+

WATCHDOG

XILINX

TB4

J5

TB5

J14

TB2

RET

ANLGOUT1

SHLD

RET

ANLGOUT2

SHLD

TB3

SHLD

GND

TPIN

+5V

RIO2

SHLD

RIO1

Battery Backup
Connection

Remote I/O
Plug

Analog Out 1
(spindle 1)

Analog Out 2
(spindle 2)

Touch Probe Connection

F2

Spare

Fuse

F1

Fuse

[ALL FUSES]
[3A/125V]

F1

Fuse

[ALL FUSES]
[3A/125V]

J14

TB5

SHLD

GND

TPIN

+5V

TB2

RET

ANLGOUT1

SHLD

RET

ANLGOUT2

SHLD

TB3

RIO2

SHLD

RIO1

WATCHDOG

XILINX

F2

Spare

Fuse

Series C Wiring Board

Battery Backup
Connection

P1
+

Remote I/O
Plug

Analog Out 1
(spindle 1)

Analog Out 2
(spindle 2)

TB4

The 9/440 resolver–based system module touch probe connection is made
to connector TB5 on the wiring board. Table 5A.A shows the location of
this connector and lists its terminal assignments.

Table 5A.A
TB5 Connector,
4 Plug-type Terminal Block Connections

Terminal

Description

Signal Destination

+5V

Probe Power

Touch Probe

TP IN

Probe Fired Signal

1

Servo Position Latch

GND

Touch Probe Common

Touch Probe

SHLD

Probe Shield

connect at module only

1

The True level (voltage transition the probe fires) is either “HIGH” or “LOW” as
defined by the AMP parameter PROBE TRANSITION. Refer to your AMP
reference manual for more information.

Important: The touch probe connector supports only +5V probing device
applications.