Section 5A
9/440 Resolver–based CNC/Drive System

5A-34

The remote I/O circuitry and connector are integral parts of the wiring
board in the 9/440 resolver–based system module. In all Series, the remote
I/O connector is mounted on the 9/440 resolver–based control wiring
board. Figure 5A.22 shows this location.

Wire connections for the remote I/O communications are made through the
TB4 NODE ADAPT connector. Connect the wires for remote I/O as
shown in the following figure. Refer to your 1771 I/O documentation for
details on making remote I/O connections.

Figure 5A.22
Remote I/O Connector in System Module (All Series)

9/440 Resolver–based

System Module

Open Cover

TB4

RIO2

SHLD

RIO1

Remote I/O
Plug

Clear

Shield

Blue

9/440 Resolver–based Control Remote I/O LED

Assuming you have:

made all necessary remote I/O communication connections on your

1771 I/O network

configured your remote I/O port for the remote I/O network in AMP

written PAL to set $RMON true during the first PAL foreground

execution, and to handle input and output words ($RMI1 – $RMI8
inputs to PAL and $RMO1 – $RMO8 outputs from PAL.)

5A.4.2
9/440 Resolver–based
Control Remote I/O
Connection