GV3000/SE AC Drive ControlNet Network Communication Option Board

N10:26

Function Loss Response

P.026

Tunable

0 = IET; 1 = Coast

N10:27

Forward/Reverse Configure

P.027

Tunable

0 = enable; 1 = rev. disable; 2 = latch

N10:28

Speed Display Scaling

P.028

Tunable

Units

N10:29

Elapsed Time Meter

P.029

Read Only

Days

N10:30

Control Bits

P.030

bit 0 = Elapsed Time Reset
bit 1 = CNI Inertia Compensation
bit 2 = CNI Speed PI Limit Enable

N10:31

Preset Speed 1

P.031

Tunable

50 = 5.0 Hz / 150 = 150 RPM

N10:32

Preset Speed 2

P.032

Tunable

50 = 5.0 Hz / 150 = 150 RPM

N10:33

Preset Speed 3

P.033

Tunable

50 = 5.0 Hz / 150 = 150 RPM

N10:34

Preset Speed 4

P.034

Tunable

50 = 5.0 Hz / 150 = 150 RPM

N10:35

Preset Speed 5

P.035

Tunable

50 = 5.0 Hz / 150 = 150 RPM

N10:36

Preset Speed 6

P.036

Tunable

50 = 5.0 Hz / 150 = 150 RPM

N10:37

Preset Speed 7

P.037

Tunable

50 = 5.0 Hz / 150 = 150 RPM

N10:38

Preset Speed 8

P.038

Tunable

50 = 5.0 Hz / 150 = 150 RPM

N10:39

Encoder Loss Enable

P.039

Tunable

0 = off; 1 = on

N10:40

Motor Overload Enable

P.040

Configurable 0 = off; 1 = on

N10:41

Motor Overload Type

P.041

Configurable 0 = nC; 1 = FC

N10:42

Line Dip Ride-Through Time

P.042

Configurable 1 = 0.1sec

N10:43

Fault Auto Reset Attempts

P.043

Configurable 0 to 10

N10:44

Fault Auto Reset Time

P.044

Configurable 8 = 8 sec

N10:45

Output Phase Loss Enable

P.045

Tunable

0 = off; 1 = on

N10:46

Reserved

P.046

Note 1

N10:47

Carrier Frequency (kHz)

P.047

Configurable 0 = 2 kHz; 1 = 4 kHz; 2 = 8 kHz

N10:48

V/Hz or Vector Regulation

P.048

Configurable 0 = V/Hz; 1 = Vector

N10:49

Country Defaults

P.049

Configurable 0 = USA; 1 = EUr; 2 = JPn

N10:50

Restore Defaults

P.050

Note 1

N10:51

Programming Disable

P.051

Tunable

Enter the password (26)*

N10:52

AUTO/MAN Key Disable

P.052

Tunable

0 = off; 1 = on

N10:53

Manual Ref. Preset Enable

P.053

Tunable

0 = off; 1 = on

N10:54

Level Sense Start Enable

P.054

Configurable 0 = off; 1 = on

N10:55

STOP/RESET Key Disable

P.055

Tunable

0 = off; 1 = on

N10:56

Reserved

P.056

Note 1

N10:57

Reserved

P.057

Note 1

* When you write to P.051, entering the password toggles disabling programming from the drive keypad. When you

read P.051, 0 = programming enabled, 1 = programming disabled.

Table 7.1 – File N10:X (Drive Read/Write Parameters)

File

Address

Parameter Name

Parameter

Number

Type

Notes

Note 1: This parameter cannot be changed from the ControlNet network, or it is reserved. When writing to this parameter, use

a value of 0. When you read this parameter, you receive a value of 0.