U.015, U.016, U.017 – Rockwell Automation GV3000/SE AC Drive ControlNet Network Communication Board, M/N 2CN3000 User Manual

Page 95: U.018, U.019, U.020, U.021, U.022, U.023, U.024

Advertising
background image

Register Map

7-5

N10:115

Torque Reg. Integral Gain

U.015

Tunable

2000 = 200.0

N10:116

Fld. Weakening Start RPM

U.016

Configurable 1785 = 1785 RPM

N10:117

Motor Top Speed

U.017

Configurable 7200 = 7200 RPM

N10:118

AC Line Volts

U.018

Configurable 460 = 460 V

N10:119

Flux Cur. Reg. Prop. Gain

U.019

Tunable

500 = 5.00

N10:120

Flux Cur. Reg. Integral Gain

U.020

Tunable

400 = 40.0

N10:121

Rotor Time Constant

U.021

Tunable

100 = 100 msec

N10:122

Motor Nameplate HP

U.022

Configurable 10 = 1.0 HP

N10:123

Low DC Bus Flt. Avoid En.

U.023

Tunable

0 = off; 1 = on

N10:124

High DC Bus Flt. Avoid En.

U.024

Tunable

0 = off; 1 = on

N10:125

Zero Speed Hold Time

U.025

Tunable

1 = 0.1 sec

N10:126

Current Compounding Gain

U.026

Tunable

1 = 0.001

N10:127

Inertia Compensation Gain

U.027

Tunable

1 = 0.001

N10:128

Losses Compensation Gain

U.028

Tunable

1 = 0.001

N10:129

Reserved

U.029

Note 1

N10:130

SVC Slip Adjust

U.030

Tunable

100 = 1.00

N10:131

SVC Sync Direction

U.031

Configurable 0 = Off; 1 = F; 2 = r; 3 = Fr; 4 = rF

N10:132

SVC Flux Cur. Reg. Gain

U.032

Tunable

500 = 500 rad/sec

N10:133

Reserved

U.033

Note 1

N10:134

Reserved

U.034

Note 1

N10:135

Reserved

U.035

Note 1

N10:136

Reserved

U.036

Note 1

N10:137

Reserved

U.037

Note 1

N10:138

Reserved

U.038

Note 1

N10:139

Reserved

U.039

Note 1

N10:140

OCL Feedback Source

U.040

Configurable 0 = TS analog in; 1 = Spd Loop PI out

N10:141

OCL Lead/Lag Select

U.041

Tunable

0 = bypass; 1 = lead/lag; 2 = lag/lead

N10:142

OCL Lead/Lag Low Freq.

U.042

Tunable

1 = 0.01 rad/sec

N10:143

OCL Lead/Lag Ratio

U.043

Tunable

1 = 1

N10:144

OCL Reference Gain

U.044

Tunable

1 = 0.001

N10:145

OCL Proportional Gain

U.045

Tunable

10 = 0.10

N10:146

OCL Integral Gain

U.046

Tunable

1 = 0.01

N10:147

OCL Trim Range Percent

U.047

Tunable

1 = 0.1% (gain of 0.001)

N10:148

OCL Prop.Trim Enable

Fil

U.048

Configurable 0 = off; 1 = on

Table 7.1 – File N10:X (Drive Read/Write Parameters)

File

Address

Parameter Name

Parameter

Number

Type

Notes

Note 1: This parameter cannot be changed from the ControlNet network, or it is reserved. When writing to this parameter, use

a value of 0. When you read this parameter, you receive a value of 0.