Register Map

7-3

N10:58

Reserved

P.058

Note 1

N10:59

Reserved

P.059

Note 1

N10:60

Node Number

P.060

Read Only

2 to 99

N10:61

Prog/Run Mode

P.061

Configurable 0 = stop,1 = not stop,

3 = term strip control

N10:62

Option Port: Communication
Loss Response

P.062

Tunable

0 = IET flt; 1 = hold last; 2 = term strip
reference; 3 = term strip control

N10:63

Option Port: Network Ref.
Source (not used)

P.063

Note 1

N10:64

Option. Port: Network Trim
Ref. Source (not used)

P.064

Note 1

N10:65

CNI Version

P.065

Read Only

5200 = CNI version 2.00

N10:66

Network Output Reg 1

P.066

Tunable

0 to 12

N10:67

Network Output Reg 2

P.067

Tunable

0 to 12

N10:68

Network Output Reg 3

P.068

Tunable

0 to 12

N10:69

Network Output Reg 4

P.069

Tunable

0 to 12

N10:70
|
N10:89

Reserved

P.070

|

P.089

Note 1

N10:90

Diagnostics Source

P.090

Tunable

0 to 19

N10:91

Diagnostics Display

P.091

Read Only

N10:92

Reserved

P.0920

Note 1

N10:93

Reserved

P.093

Note 1

N10:94

Reserved

P.094

Note 1

N10:95

Power Module Output Amps

P.095

Read Only

100 = 10.0 A

N10:96

Reserved

P.096

Note 1

N10:97

Reserved

P.097

Note 1

N10:98

Software Version Number

P.098

Read Only

600 = version 6.00

N10:99

Power Module Type

P.099

Read Only

4.005 = 460 V, 5 HP

H Parameters

N10:100

Motor Nameplate Volts

H.000

Configurable 460 = 460 V

N10:101

Motor Nameplate Base Freq

H.001

Configurable 600 = 60.0 Hz

N10:102

Motor Nameplate Amps

H.002

Configurable 100 = 10.0 A

N10:103

Torque Boost Voltage

H.003

Configurable 5 = 0.5%

N10:104

Slip Compensation

H.004

Tunable

0 = 0.0%

N10:105

DC Braking Enable

H.005

Tunable

0 = off; 1 = on

N10:106

DC Braking Start Frequency

H.006

Tunable

50 = 5.0 Hz

Table 7.1 – File N10:X (Drive Read/Write Parameters)

File

Address

Parameter Name

Parameter

Number

Type

Notes

Note 1: This parameter cannot be changed from the ControlNet network, or it is reserved. When writing to this parameter, use

a value of 0. When you read this parameter, you receive a value of 0.

Advertising