3-2. To Start Counting
1. Press the STANDBY/OPERATE key to turn the scale on when displaying the standby
indicator. Or press the RESET key to clear
any previous operations.
2. Three LED’s on the UNIT WEIGHT BY keys
will blink. This is to prompt you to select a
method for entering a unit weight for operation.
3.
S
elect one of the ways to enter or recall the unit weight (the weight of one item of
what you are counting), and refer to the section noted for more instructions.
STABL
.
888881
0
SFV
:
: ( , * + 7 N J
1213456789
0.000
$ 6 $ 0 3
8 : J
12341567
0.00000
4567890123456
7
TARE
ENTERED
ZERO
M+
SCALE
TOTAL
UNIT WEIGHT BY
KEY-
BOARD
You can return to this point at any time during
operation by pressing the RESET
key.
(This doesn’t clear the entered tare weight
and M+ memory.)
RESET
SAMPLE
ID.
By using a sample: Section “
3-3. Unit Weight By Samples”
10 sample size
5, 25, 50 or 100 sample size
Desired sample size
Desired sample size not to use the
SAMPLE
key
By using the l0-key pad: Section
“33-4.Unit Weight By KEYBOARD”
By stored lD number: Section“
3-5.Unit Weight By ID Number”