F-05-05, F-05-06, F- x-01 – Rice Lake FC-i/Si Series, A&D Weighing User Manual
Page 42
Upper Limit.
0
Enter via the 10-key pad.
Use the
-
or
.
key to “set minus value.
010
Lower Limit.
0
Enter via the 10-key pad.
Use the
-
or
.
key to set minus value.
f-05-03
f-05-04
A Beeper With Comparator Results.
These are beeps for the comparator, not for the key
operation.
000
All Comparator Beepers are OFF.
Example:
The OK beep sounds – HI & LO doesn't
sound. The scale will beep continuously
when display meets OK condition.
f-05-05
000
0
= Beeper OFF
1
= Beeper ON
HI LO
OK
Factory Use.
0
This setting should be “0”.
f-05-06
F-06-X/F-07-X/F-08-X Data Output
f-06-X for standard RS-232C,
f-07-X for Ch.1 (PORT 1) and
f-08-X for Ch.2 (PORT 2).
Data Out Mode
0
Key mode: Data is sent by pressing the PRINT key.
+ command mode.
1
Stream mode: Data is sent continuously.
command mode cannot be used.
2
Auto-print mode A: Data is sent if the weight display is stable
at +5d (weighing display division) and above.
+ command mode.
3
Auto-print mode B: Data is sent if the weight display is
stable, at ±5d (weighing display division) and above/below.
+ command mode
4
Command mode only.
5
To use as Bar Code Reader Interface.
6
UFC format with Key Mode (see setting “
0”).
7
UFC format with Auto-Print Mode A (see setting “
2”).
8
UFC format with Auto-Print Mode B (see setting “
3”).
f-
X-01
06
07
08