Data Format (f-06/07/08-03)

‰ Format for AD-8121 MODE 1 or 2. (f-06

/

07

/

08-03="0")

‰ Format for AD-8121 MODE 3. (f-06

/

07

/

08-03="1")

‰ Format for general apparatuses, computers, etc. (f-06

/

07

/

08-03="2")

Baud Rate (f-06/07/08-04)

Select the baud rate according to the device to be connected.
‰ 2400 bps (f-06

/

07

/

08-04="0")

Select 2400 bps to connect with an AD-8121.

‰ 4800 bps (f-06

/

07

/

08-04="1")

‰ 9600 bps (f-06

/

07

/

08-04="2")

12-3. Connecting the AD-8121 Printer / MODE 1 or MODE 2

‰ When using the AD-8121 printer (MODE1 or MODE 2), you will be able to get data:

Number of data items, total, maximum, minimum, mean value, range of data
(max. - min. data) and standard deviation.

‰ When using the AD-8121 with MODE 2, set f-06/07/08-02 to print pcs (count) data

only or weight data only.

‰ To print date and time, use the AD-8121’s calendar / clock function and set

f-06/07/08-2 to print pcs (count) data only or weight data only.

Print Operations Settings

Print By:

F-Function

f-06/07/08-01

Printer MODE

FC PRINT key

0

MODE 1

Auto Print

2 or 3

MODE 1

Printer DATA key

1

MODE 2

Example of f-06/07/08-02 settings

‰ To print pcs (count) data only: set f-06/07/08-02 at "00100"

‰ To print weight data only: set f-06/07/08-02 at "00010"

‰ To print pcs (count) and weight data: set f-06/07/08-02 at "00110"

‰ To print pcs, weight and Unit Weight data: set f-06/07/08-02 at "00111"

‰ To print total data (accumulated by the M+ key), press the TOTAL key so the

Count display shows the total, then press the PRINT key.

‰ If you are using the AD-8121’s statistic functions, then set f-06/07/08-02 at

"

001#0" (# = 0 or 1) for pcs (count) data or "00010" for weight data.

‰ MODE 1 and 2 of the AD-8121 can not print ID numbers.