13-2. OP-02 Ni-MH Battery Pack

Using OP-02 Battery Pack

‰ By using the OP-02 Ni-MH battery pack, the scale can be operated for around 10

hours, after a full charge and using no other options

.

1. After making sure that the battery switch on the battery pack is "OFF" position,

insert the battery pack firmly into the rear side of the scale.

Battery Switch

Lock Screw

OP-02 Slot

2. Tighten the lock screw on the battery pack.

3. When desired, turn the battery switch on to supply power to the scale. The display

will come on after its self-check.

4. Use the

STANDBY/OPERATE key to

turn the display on or off. When the
scale is in standby mode,
a period appears in the
weight display as an
indicator.

When the count display shows “

lo bat” for low

battery, the battery power is almost exhausted
and should be recharged.

Before getting to low battery, the display will
show “

lo bat” on and off to indicate that the

battery power is coming close to low battery.

The STANDBY/OPERATE key only turns the display on or off (and
keeps the scale warmed up on standby). When the scale is not used
for a long periods, switch the battery switch to "OFF" position.

Recharging the Battery

1. Turn the battery switch off on the battery pack.