‰ Data to be Sent.

00100

 Count data sent.

You select which data to be sent by keying in a

0

or

1

for the data: Date, ID no., PCS

(count), weight or unit weight.
Example: Key in

0

1

1

0

0

to

display

01100, this setting would send only the ID

number and the count.

f-

X-02

06

07

08

00000

Weight
PCS(count)

Date/Time Unit
ID Weight

‰ Data Format

0

 Format for AD-8121 MODE 1.

1

Format for AD-8121 MODE 3.

No difference between “

0”

and ”

1” when used with the

UFC format.

2

Format for general apparatuses, computers, etc.

f-

X-03

06

07

08

‰ Baud Rate

0

 2400 bps.

1

4800 bps.

2

9600 bps.

f-

X-04

06

07

08

‰ Data Length and Parity

0

 7 bits, even parity.

1

7 bits, odd parity.

2

8 bits, non parity.

f-

X-05

06

07

08