Acknowledgment and error codes – Rice Lake FC-i/Si Series, A&D Weighing User Manual

Page 53

Advertising
background image

Command

Definition

Notes

MR

Store the unit weight and tare weight into the specified ID
memory.

MI

Store the item code into the specified ID memory.

ML

Store the comparator limits into the specified ID memory.

MA

Store the total count and number of additions into the
specified ID memory.

Refer to the data
format for the reply.

CM

Clear the specified ID memory contents

“CM,1.23C

R

L

F

” clears

content of

id000123.

?FC

Send the specified F-Function setting.

FC

Store the specified F-Function setting value.

Refer to the data
format for the reply.

Acknowledgment and Error Codes

When the scale receives an external command, it reacts as follows:

‰ If the command requests a data reply, the scale will send the data.

For other commands, the scale will send an acknowledgment <AK> (06H) upon
acceptance of the command.

‰ If the command is I

,

S

,

T

or

Z , the scale will send a second acknowledgment

<AK> (06H) when the command operation is completed.

If an error occurs, the scale will send an error code.

‰ The error format is

E C ,

E n

C

R

L

F

, "n" being the error number.

En

Definition

Notes

E0

Communication error

Parity error, framing error, etc.

E1

Undefined command error

The command does not exist for the scale.

E2

Scale not ready error.

The scale is not in a state where a command
could be expected.

E4

Too many characters error

The command contains too many characters.

E6

Format error

The command contains invalid characters.

E7

Out of range error

Value is out of range. The tare weight is more
than the capacity, etc.

Advertising