Selecting the statistical items to output, Selecting the unit – Rice Lake FX-i WP Series, A&D Weighing User Manual

Page 23

Advertising
background image

21

Selecting the statistical items to output

5 Press

the

SAMPLE

key to display 5taf 0 .



6 Press

the

RE-ZERO

key to select the output items.

In the example, 5taf 1 is selected to output the number of data,
sum, maximum, minimum, range (maximum-minimum) and average.

Parameter Description

0

Number of data, sum

1

Number of data, sum
Maximum, minimum, range (maximum – minimum), average

2

Number of data, sum
Maximum, minimum, range (maximum – minimum), average,
Standard deviation, coefficient of variation


7 Press

the

PRINT

key to store the setting.


Note
The statistical calculation mode will be enabled using
the ON:OFF key or when the power is turned on.


8 Press

the

CAL

key to return to the weighing mode.

Selecting the unit

9 Press

the

MODE

key to select the unit to be used for

the statistical calculation mode.


Notes
Selecting the unit using the MODE key is not available after the data
is entered. In this case, clear the data as described on page 24 and
select the unit using the MODE key.

When the unit used for the statistical calculation mode is to be enabled
upon power-on, select the unit in “Unit (
Unit)” of the function table
beforehand.

Advertising