8 load cell wiring – Rice Lake IQ 700 Configurable Weight Indicator User Manual

Page 10

Advertising
background image

6

IQ 700 Installation Manual

NOTES:

Unprotected cable runs need to be installed in a method to protect the cable from damage from crimping.

All wiring must conform to the National Electrical Code and RP 12.6.

2.8

Load Cell Wiring

Units are equipped with a six-wire load cell connection.
Figure 2-5 shows the load cell output connector and the
location of TB1 on the back of the indicator. Table 2-2
(in the following column), shows load cell connector
pin assignments.

Figure 2-5. J1 Load Cell Connector

A

B

C

D

E

F

J1

Load Cell
Connector

TB3 & 5

REAR VIEW

TB1

POWER

TB2 & 4

Pin

Function

A

+EXCITATION

B

–EXCITATION

C

+SIGNAL

D

–SIGNAL

E

+SENSE

F

–SENSE

Table 2-2. Load Cell Connector Pin Assignments