Options Configuration

29

4.5

Option 5 – Expanded Serial Communications

The expanded serial communications options provide RS485 communications for the IQ 700. Option 5 features
include:

Duplex communication for up to two weight indicators on a single serial port.

RS485 half-duplex with U21 installed.

RS485 full-duplex available with U21 and the

KBT7116-13

kit installed.

Direct keyboard access to the indicator address in normal operating mode.

Poll/answer protocol.

Unit address 1 - 98.

Tag mode that adds the programmed address to standard serial output format.

Stored ID mode allows an identification number to be held until written over by a new one.

Counter sequentially counts on each valid print. Counts from 1 – 999,999.

TAG/LAN

Under option 5 there are two modes of serial operation that can be selected:

TAG mode – Adds a two digit address to the standard serial format which “tags” printed data with the IQ
700’s address. This feature is useful when more than one indicator is set up on a site and serial data needs to
be identified with the indicator from which it was generated.

LAN mode – Local Area Network can be configured as a two wire (half duplex) RS485 serial
communication by installing the driver chip into socket U21 or 5.2 LAN (full duplex) RS485/RS422 with
the additional installation of the KBT7116-13 kit.

Table 4-7. Option 5 Configuration

NOTE: Port 1 configuration (parameter 14) must be set for duplex, (du), demand mode (de), and the appropriate
baud rate. See Section 3.2 for wiring and serial protocol.

The option 5 configuration parameters are graphically illustrated in Figure 4-10, shown on the page 29.

Option

Prompt Display

Explanation

Additional Notes

OP.5

OP.5 oF
OP.5 on

off
on Option 5 enabled

5.1. tAg
LAn

Tag mode (data labeled with an address
Local Area Networking (RS485)

5.2. Addr

Allows selection of indicator address from
1 – 98).

When either 5.2 or 5.5 is selected, the display
alternates between 5.2 Addr or 5.5 cnt, respectively
and its current numeric value. The alternation of the
display occurs until a new value is selected.
Addresses can be accessed in the normal
operating mode by pressing

0

and

5

simultaneously. Pressing

0

and

2

for several

seconds allows changes to be made without having
to access the dip switches. To exit, press

TARE

RECALL

for

several seconds.

5.3. oF
on

ID held option off
ID option enabled

5.4. oF
on

Counter off
Counter option enabled

5.5. cnt

Preset initial counter value from 0 – 999,999

See notes from 5.2