5 full duplex parameter entry/recall, 2 delay demand print, 3 battery option – Rice Lake IQ 700 Configurable Weight Indicator User Manual

Page 68: 2 delay demand print 8.3 battery option, The response data, Indicating the invalid portion

Advertising
background image

64

IQ 700 Installation Manual

8.1.5

Full Duplex Parameter Entry/Recall

One of the capabilities of the IQ 700, with the full duplex serial port 1 is the ability to enter or recall setpoints from
a computer or terminal. The following table illustrates full duplex setpoint parameter entry/recall.

Table 8-2. Full Duplex Setpoint Parameter Entry/Recall

The response data (

xxxxx

) is corrected for count-by round off and is six characters in length if there is no decimal

point and seven with the decimal point. Leading zeros are spare characters.

Invalid data requests or entries are responded to with an echo of the valid portion and an

I

indicating the invalid

portion.

8.2

Delay Demand Print

When file 7.17 is enabled, a demand print, from either the print key or the remote print (TB3-10), is delayed for up
to 25 seconds if the scale is in motion. If the scale comes out of motion before the 25-second timer times out, the IQ
700 will do a print of the data. If the scale remains in motion, the demand print is aborted.

8.3

Battery Option

The IQ 700 has an optional battery that can be installed. The indicator enclosure must be opened to connect the
battery to the CPU board. Use the following steps:

1. Disconnect AC power by uplugging the indicator.

2. Remove the screws that hold the front bezel to the enclosure body.

3. Place the indicator face down on an antistatic work mat, then lift the back of the indicator away from the front

bezel.

4. Set the enclosure aside.

5. Locate the battery plug in on the CPU board (J6) shown in the diagram below.

Figure 8-5. Battery Location

6. Plug other end into battery located on the enclosure backplate.

Setpoint Parameter

SE<n> (entry)

SR<n> (recall)

0

1

2

3

4

5

6

Mode A

all

SP1

SP2

Mode B

all

SP1

Pr1

SP2

Pr2

Mode C

all

SP1

dr1

SP2

dr2

Mode D

all

SP1

Pr1

dr1

SP2

Pr2

dr2

Mode E

all

SP1

Pr1

dr1

HI

Lo

Mode F

all

SP1

HIGH

Mode G

all

SP1

LOW

HIGH

J7

K1

S3

J5

J3

F1

J6

TB5

TB1

–EXC

–SEN

–SIG

+SIG

+SEN

+EXC

6

5

4

3

2

1

LOAD CELL CONNECTOR

1

2

U2

Q5

U18

GND LO HI

TO POWER SUPPLY

CPU Plug in

for Battery

Advertising