Modes A, B, C, and D can be used in a independent straight setpoint system or as part of either a manual batching or
automatic batching system. When configured for batching, the setpoints are de-energized except when the batch is
in process. When the setpoint cutoff is reached, the setpoints are latched and will not reactivate until the next
batching sequence.

Modes E, F, and G are dependent modes.

A zero band (ZBD) selectable from ±1 to ±50 displayed graduations around 0 is available in all modes except Mode
C or Mode D, for monitoring an empty scale.

The setpoint parameters are defined in

Table 7-2.

Table 7-2. Setpoint Parameter Definitions

NOTES:

Display indication 11.---- is a default condition created during setup changes to other parameters (

Err 1

).

Re-enter to clear.

Logic levels on TB-3 are on at 0VDC (current sinking) and off at 5VDC.

Front panel LED’s for setpoints 1 and 2 follow logic level outputs.

Setpoints track display readings and will therefore be affected by Gross/Net and Auto Tare operations.

In batching modes (

BAT1

and

BAT2

) the setpoint outputs are latched.

Internal jumpers S4 and S5 must be in 2-3 position to enable the front panel start switch (S21).

Table 7-3 lists setpoint selections, subparameter information, and their explanation.

Parameter

Description

ID

Output Change

Setpoint

Weight value desired at the end of a weighing operation.

SP

Wt > or = SP

Preact

Weight value which is set to allow for material in suspension.

Pr

WT > or = SP – Pr

Dribble

Weight value at which material flow changes, usually from
fast to slow feed.

dr

WT > or = SP – dr – Pr

Tolerance Band

Weight band around the setpoint

HI, Lo

HI > WT > Lo

Zero Band

Weight band ± around 0 used to define an empty scale.

ZBD

0 + x > WT > 0 – x

(where x = 1 thru 50)

Parameter Data

Selection

Subparameter

Selection

Subparameter

Data Selection

Explanation

Net/Gross

Tare

Lb/Kg

Key which affects associated parameters

11 oFF

N/A

N/A

Setpoints off. Zero band (parameter 12) still functional

11 SP

Setpoint operation

11.1

11.1oFF
11.1 SI
11.1S1.P
11.1S1.d
11.1S.P.d.

Setpoint 1 = off
Setpoint 1 = Mode A
Setpoint 1 = Mode B
Setpoint 1 = Mode C
Setpoint 1 = Mode D

11.2

11.2POS
11.2zEr

Setpoint 1 is off when weight < SP
Setpoint 1 is on when weight < SP

11.3

11.3oFF
11.3 S2
11.3S2.P
11.3S2.d
11.3S.P.d
11.3.toL

Setpoint 2 = off
Setpoint 2 Mode A
Setpoint 2 Mode B
Setpoint 2 Mode C
Setpoint 2 Mode D
Setpoint 2 Mode E

11.4

11.4.POS
11.4.zEr

Setpoint 2 is off when weight < SP
Setpoint 2 is on when weight < SP

Table 7-3. Parameter 11 Configuration Selections